 Sales reps: Kazuyoshi Morino / Masaru Serizawa

Compact Reflective BeatSensor (BS-R1700)  long wavelength type


Product Name Compact Reflective BeatSensor
Model BS-R1700
Sensing Method Near-Infrared reflection method
Spectroscopic Method Polychromator
Wavelength Range 900~1700 nm
Measurement distance 50~100 mm
Measurement field diameter φ15~20 mm
Light Source Tungsten lamp (average lifespan 20,000 hours)
Communication LAN (TCP/IP) Wired LAN / Wireless LAN
Operating Temperature 0~40℃
Power (input) DC 12 V, 50 W
Weight 7 kg
Dimensions 250 (W) x 167 (H) x 182 (D) mm
PC Software Standard feature (for Windows)
Easy preparation of calibration curves, graph drawing, and measurement recording

Product Name BeatSensor Power Unit
Model BS-AC
Power (input) AC 100 V~120 V / AC 220 V~240 V
(50/60 Hz)
Power (output) DC 12 V (80W or less)
Weight 3 kg
Dimensions 254 (W) x 87 (H) x 150 (D) mm


Compact Reflective BeatSensor (BS-R1000)  short wavelength type


Product Name Compact Reflective BeatSensor
Model BS-R1000
Sensing Method Near-Infrared reflection method
Spectroscopic Method Polychromator
Wavelength Range 640~1050 nm
Measurement distance 50~100 mm
Measurement field diameter φ15~20 mm
Light Source Tungsten lamp (average lifespan 20,000 hours)
Communication LAN (TCP/IP) Wired LAN / Wireless LAN
Operating Temperature 0~40℃
Power (input) DC 12 V, 50 W
Weight 5 kg
Dimensions 190 (W) x 167 (H) x 132 (D) mm
PC Software Standard feature (for Windows)
Easy preparation of calibration curves, graph drawing, and measurement recording

Product Name BeatSensor Power Unit
Model BS-AC
Power (input) AC 100 V~120 V / AC 220 V~240 V
(50/60 Hz)
Power (output) DC 12 V (80W or less)
Weight 3 kg
Dimensions 254 (W) x 87 (H) x 150 (D) mm


Compact Fiber BeatSensor (BS-F1700)  long wavelength type


Product Name Compact Fiber BeatSensor
Model BS-F1700
Sensing Method Near-Infrared fiber-optic system
Spectroscopic Method Polychromator
Wavelength Range 900~1700 nm
Available Probes Optional  See each probe section
Light Source Tungsten lamp (average lifespan 20,000 hours)
Communication LAN (TCP/IP) Wired LAN / Wireless LAN
Operating Temperature 0~40℃
Power (input) DC 12 V, 50 W
Weight 6 kg
Dimensions 190 (W) x 167 (H) x 250 (D) mm
PC Software Standard feature (for Windows)
Easy preparation of calibration curves, graph drawing, and measurement recording

Product Name BeatSensor Power Unit
Model BS-AC
Power (input) AC 100 V~120 V / AC 220 V~240 V
(50/60 Hz)
Power (output) DC 12 V (80W or less)
Weight 3 kg
Dimensions 254 (W) x 87 (H) x 150 (D) mm


Compact Fiber BeatSensor (BS-F1000)  short wavelength type


Product Name Compact Fiber BeatSensor
Model BS-F1000
Sensing Method Near-Infrared fiber-optic system
Spectroscopic Method Polychromator
Wavelength Range 640~1050 nm
Available Probes Optional  See each probe section
Light Source Tungsten lamp (average lifespan 20,000 hours)
Communication LAN (TCP/IP) Wired LAN / Wireless LAN
Operating Temperature 0~40℃
Power (input) DC 12 V, 50 W
Weight 6 kg
Dimensions 190 (W) x 167 (H) x 250 (D) mm
PC Software Standard feature (for Windows)
Easy preparation of calibration curves, graph drawing, and measurement recording

Product Name BeatSensor Power Unit
Model BS-AC
Power (input) AC 100 V~120 V / AC 220 V~240 V
(50/60 Hz)
Power (output) DC 12 V (80W or less)
Weight 3 kg
Dimensions 254 (W) x 87 (H) x 150 (D) mm


BeatSensor GP2

Product Name BeatSensor GP2
Model BSS1700HO-SMA-FA
Sensing Method Near-Infrared fiber-optic system
Spectroscopic Method Polychromator
Wavelength Range 900~1700 nm
Available Probes Optional  See each probe section
Light Source Tungsten lamp (average lifespan 20,000 hours)
Power (input) AC 100 V (50/60 Hz)
Weight 18 kg
Dimensions 300 (W) x 284 (H) x 400 (D) mm
Software for preparing calibration curves Optional  The Unscrambler


Transmission Probe for Cells and Vials


Product Name Non-branching single-core fiber cable
Model
2 m: SFA02SMA-UL
5 m: SFA05SMA-UL
 10 m: SFA10SMA-UL

    For square cells (transmission)
Product Name Transmission probe for flow cells
Model TA020-FC
Compatible Cells Offline use: glass cell / quartz cell
In-line use: flow cell + tube + pump
Optical Path Length 2 / 5 / 10 / 20 mm
Measurement Field Diameter φ3 mm
Dimensions 115 (W) x 56 (H) x 30 (D) mm

    For vials / screw cap vials (transmission)
Product Name Transmission probe for vials
Model TA-V
Compatible Cells Screw cap vial (φ11.7 mm)
Measurement Field Diameter φ3 mm
Dimensions 100 (W) x 55 (H) x 50 (D) mm


Immersion-type Transmission Probe

Product Name Immersion probe
Optical Path Length 5 / 10 / 20 mm
Measurement Field Diameter φ3 mm
Dimensions 300 (W) x φ25 mm






Reflection Probe with Tiny Spot Diameter

Product Name Bifurcated 7-core fiber cable
Model 2 m: BFA022SMA-UL
5 m: BFA052SMA-UL
Measurement Distance 0~10 mm
Measurement Field Diameter φ3 mm

For vials / screw cap vials (reflection)  perfect for suspension
Product Name Reflection probe for vials
Model RA-V
Measurement Field Diameter φ3 mm





Reflection Probe with High Light Intensity and Small Spot Diameter

Product Name Reflection probe 50 mm
Model RA050
Measurement Distance 30~50 mm
Measurement Field Diameter φ8 mm
Dimensions 130 (W) x φ60 mm

 